Access Granted | A user has presented a credential to a door and they have been granted access |
Access Pending Door Credential Denied | A user has been denied access through a door because the attempt occurred before the user's Valid From date |
ACU Bus New Node | A new Expansion controller has been detected on the ACU Bus |
ACU Bus Node Address Not Assigned | |
ACU Bus Reset | The ACU Bus has been reset |
Barred Door Credential Denied | A user has been denied access because they have been barred through the VOLO website |
Connected | A controller has connected to the VOLO cloud |
Disconnected | A controller has disconnected from the VOLO cloud |
Door Closed | A door has closed |
Door Credential Denied | A user has been denied access because they do not have permission to unlock it |
Door Credential Unlocked | A door has unlocked because a user with the appropriate permissions has presented a credential |
Door Exit Button Unlocked | A door has unlocked because someone has pressed the Exit Button |
Door Forced | A door has been opened but the lock was not released by an Exit Button or credential presentation |
Door Held Open | A door has been open for longer than is allowed by the Door Held Open setting |
Door Holiday Credential Denied | A user has been denied access because they do not have permission to unlock it. The door is operating a Holiday schedule which might impact the permissions required for this door. |
Door Holiday Credential Schedule Active | A holiday is in operation on this door |
Door Holiday Credential Unlocked | While a holiday is in operation, a door has unlocked because a user with the appropriate permissions has presented a credential |
Door Holiday Schedule Locked | While a holiday is in operation, a door has automatically locked on a schedule |
Door Holiday Schedule Unlocked | While a holiday is in operation, a door has automatically unlocked on a schedule |
Door Holiday Unlock Schedule Active | A holiday unlock schedule is in operation on this door |
Door Lockdown Disabled | The lockdown has been disabled on this door |
Dor Lockdown Enabled | This door has been locked down (no users may unlock the door unless they are configured as exempt from lockdown) |
Door Locked | A door has locked |
Door Opened | A door has opened |
Door Remote Unlocked | A door has been remotely unlocked through the VOLO website |
Door Timezone Locked | A door has automatically locked according to an unlock schedule |
Door Timezone Schedule Active | An unlock schedule is active on this door |
Door Timezone Unlocked | A door has automatically unlocked according to an unlock schedule |
Exit Button Pressed | An exit button has been pressed |
Exit Button Released | An exit button has been released |
Expired Door Credential Denied | A user has been denied access through a door because the attempt occurred after the user's Expires date |
Fire Alarm Active | A Fire Alarm has been triggered |
Fire Alarm Inactive | A Fire Alarm has been reset |
Fire Alarm Unlocked | A door has unlocked in response to a fire alarm being triggered |
General Input 1 High | The input pin has been disconnected from 0V |
General Input 1 Low | The input pin has been connected to 0V |
General Input 2 High | The input pin has been disconnected from 0V |
General Input 2 Low | The input pin has been connected to 0V |
General Input 3 High | The input pin has been disconnected from 0V |
General Input 3 Low | The input pin has been connected to 0V |
General Input 4 High | The input pin has been disconnected from 0V |
General Input 4 Low | The input pin has been connected to 0V |
General Output 1 Active | The output pin has been connected to 0V (internally) |
General Output 1 Inactive | The output pin has been disconnected from 0V (internally) |
General Output 2 Active | The output pin has been connected to 0V (internally) |
General Output 2 Inactive | The output pin has been disconnected from 0V (internally) |
Hardware Reset | A controller has been reset to factory settings |
Last Will Disconnect | A master controller has lost connection with the VOLO cloud |
Lockdown Door Credential Denied | A user has been denied access through a door because the door is currently locked down |
Lost Door Credential Denied | A user has been denied access through a door because they have used a credential that has been flagged as lost through the VOLO website |
PSU Fail | A controller has lost its mains power supply and has reverted to battery backup |
PSU OK | A controller has returned to using the mains power supply |
Remote Reset Occurred | A controller was reset remotely, through the VOLO website |
Tamper Active | A controller cabinet lid has been closed/replaced |
Tamper Inactive | A controller cabinet lid has been opened/removed |